Commissioners and Citizen Advisory Boards Services and Programs County Departments, Courts and Services List County Directories and Services A to Z County Jobs
 
Community Calendars County Home Page

Kalamazoo County Drain Commissioner

STORMWATER MANAGEMENT RULES

DESIGN STANDARDS FOR STORMWATER MANAGEMENT FACILITIES

ADDITIONAL DESIGN REQUIREMENTS FOR SURFACE WATER DISCHARGE TO THERMALLY SENSITIVE STREAMS

1. When surface water discharge is within a watershed where thermal impacts (cold water streams and designated drains) are a primary concern, deep wet detention basins shall be required.

2. The permanent pool must be a minimum of 8 feet deep. See Appendix H for a listing of cold water designated drains and streams in Kalamazoo County.

3. Additional shade plantings shall be required on the west and south sides of drainage facilities.

4. Onsite infiltration of stormwater should be considered where site conditions allow.